Search found 4387 matches
- Tue Mar 03, 2009 11:56 am
- Forum: Solid State
- Topic: A370
- Replies: 12
- Views: 9261
A370
Hi Chaps, I've noticed on powering down the amp,it takes a while for the supply caps to discharge-not surprising with 100,000 uF a side!-and just as the caps are discharged,there is clicking and popping/beeping noises from each speaker.It's not the same through each channel i.e. each channel does it...
- Tue Mar 03, 2009 10:09 am
- Forum: Speakers
- Topic: Stompen und Fonken.
- Replies: 276
- Views: 121537
- Tue Mar 03, 2009 9:45 am
- Forum: Assorted Stuff
- Topic: SimonFest - thanks
- Replies: 20
- Views: 9710
- Thu Feb 26, 2009 10:15 pm
- Forum: Assorted Stuff
- Topic: Youthful desires (hi-fi)
- Replies: 21
- Views: 10901
Well I'm getting the MF because the KEL is getting used all day every day up here with a sky+ box feeding it,radio during the day,and tv at night.I think it's a bit of a waste of a good valve amp,so I was going to get a Jungson Chinese sand jobbie with a claimed 80w class a(loads of good things said...
- Thu Feb 26, 2009 1:58 pm
- Forum: Everyones Projects
- Topic: 26 10Y KR300BXLS
- Replies: 470
- Views: 153047
- Thu Feb 26, 2009 1:41 pm
- Forum: Everyones Projects
- Topic: 26 10Y KR300BXLS
- Replies: 470
- Views: 153047
- Thu Feb 26, 2009 1:32 pm
- Forum: Everyones Projects
- Topic: 26 10Y KR300BXLS
- Replies: 470
- Views: 153047
It wasn't live,if it was it would have exploded! the arc comes from induction in the busbars that run across site next to circuits that are energised.Here's some links to give you an idea.These are a lot more impressive than we managed,though we had to do ours half a dozen times so everyone could ge...
We were opening and closing an isolator on a 275kV sub yesterday,just to get a good arc.Must've been a good 3-4 feet,and the noise was unbelievable.Good fun :shock: Just back from seeing Snow Patrol at the Glasgow SECC.We were right at front centre.What a great gig! Sore feet now.Must be getting old.
- Wed Feb 25, 2009 12:38 pm
- Forum: Solid State
- Topic: Sand amp chassis ?
- Replies: 33
- Views: 18945
The building with the danger of death notice will probably be a little distribution sub,containing an 11kV to 415v transformer or two,and maybe a small suite of 11kV switchgear,one(or two) of which will feed the trannie(s) in the sub,the others will feed 11kV to other(possibly smaller) little dist. ...